NOVOTECHNIK传感器TMI-1000-002-423-102技术参数
Series | TMI |
Defined electr. range | 1000mm |
Mech. configuration | 002: Screw flange M 18x1.5 |
Electrical Interface | 4: Analogue Interface, supply voltage 24 VDC ±20 % |
Output signal Analogue Interface 4_ _ | 2: Current output |
Analogue Interface current output 42 _ | 3: 4 mA...20 mA |
Electrical connection | 102: 8 pin round connector M 12x1 |
NOVOTECHNIK传感器TMI系列介绍
带模拟接口的 TLM/TMI 传感器的起始和终止位置可根据具体应用进行调整。输出范围(0..10 V / 10..0 V / 0..20 mA / 等)可完全重新定义。最多两个位置标记可以通过两个连接器引脚和简单的编程程序同时重新校准。重新编程后,仍能保证指定的线性度。
编程
必须将位置标记置于所需的新起始位置。在连接器引脚 8 (PROG) 上施加至少 3 秒的高电平后,将激活编程模式。之后,在引脚 4 (DIAG) 上施加至少 3 秒的高电平至低电平转换,将设置起始位置。然后,必须将位置标记置于所需的终止位置。下一次施加至少 3 秒的低电平高电平至低电平转换,将设置终止位置。现在必须先恢复引脚 4 的低电平,然后再恢复引脚 8 的高电平。
如果使用带有两个位置标记的系统,则两个位置必须同时重新编程。
如果编程过程未在 60 秒内完成,即引脚 8 (PROG) 上升沿与接管终端位置之间的时间超过 60 秒,则起始/终端位置将被忽略,并且不会写入传感器的 EEPROM。
连续编程的条件:
- 时间必须满足以下条件
- 终端位置必须大于起始位置
- 不得出现错误情况,例如,如果使用带有两个磁铁的系统,则两个磁铁都必须正常工作
The start and end position on TLM/TMI transducers with analog interfaces can be adjusted for application specific purposes. The output range (0..10 V / 10..0 V / 0..20 mA / etc.) can be completely redefined. Up to two position markers can be recalibrated at the same time via two connector pins and a simple programming procedure. After reprogramming the specified linearity is still guaranteed.
Programming
The position marker(s) has to be placed at the desired new start position(s). The programming mode will be activated when high level is applied at connector pin 8 (PROG) for at least 3 seconds. After that a high to low transition at pin 4 (DIAG) with a minimum duration of 3 seconds will set the start position(s). Then the position marker(s) has to be placed at the desired end position(s). The next high to low transition with a low level of at least 3 seconds will set the end position(s). Now the low level at pin 4 and then the high level at pin 8 has to be taken back.
If a system with two position markers is used, always both positions are reprogrammed at the same time.
If the programming procedure is not completed within 60 seconds, i.e. the time between the rising edge at pin 8 (PROG) and the take over of the end position exceeds 60 seconds, the start/end position is ignored and not programmed into the transducer's EEPROM.
Conditions for successive programming:
- the timing has to meet the conditions
- the end position(s) must be greater than the start position(s)
- an error condition must not be present, e.g. if a system with two magnets is used, both magnets have to be functional
NOVOTECHNIK传感器其他常用型号:
NOVOTECHNIK TMI-1000-002-423-102
NOVOTECHNIK TM1-0150-002-423-101
NOVOTECHNIK TMI-0400-008-222-301
NOVOTECHNIK TMI-0500-008-222-301
NOVOTECHNIK TMI-0700-008-222-301
NOVOTECHNIK TMI-0900-008-222-301
NOVOTECHNIK TRANSDUCER NEW + ORIGINAL+ ONE YEAR WARRANTY
爱泽工业成立于2010年,定位于向制造工业提供高端制造技术和设备。代理经营世界优质的电气自动化、机械与传动、流体控制、仪器仪表、工具等产品。作为电气,液压以及气动解决方案的合作伙伴,我们利用我们的全球协作团队,为客户提供先进解决方案,市场知识以及相关增值服务来帮助优化客户的工作效率,提高可靠性和安全性,致力于成为工业产品和解决方案的优质渠道。
如果有任何关于NOVOTECHNIK传感器TMI-1000-002-423-102的疑问,请随时与我们沟通(021-31006702)。我们将尽全力解决您的问题。
If you have any question for NOVOTECHNIK products, please feel free to dial 0086-21-3100 6702/ send request email to sales@ize-industries.com / browse our website:www.ize-industries.com.
NOVOTECHNIK传感器TMI-1000-002-423-102技术参数